HW-250F Power Relay 250A, Durable, Bolt Mounting

Model: HW-250F

Product Characteristics:

①Strong structure, strong impact resistance, strong vibration resistance and long service life.

②Load switching current: 250A.

③Provide 1 set 250A of contact conversion.

④Retaining bolt installation.

Additional information

Contact resistance

≤100mΩ

Electrical life

≥3×10⁴ times

Mechanical life

≥10⁶ times

Rated coil power

DC: 2.0W AC: 4VA

Suction time

≤25ms

Product Details

Model Description

HW 250F 1 Optional Optional D VDC

①Enterprise code: Hangwang Electric

②Serial number: 250F

③Number of contact groups: 1

④Contact form: (Z-conversion type  H-normally open type  D-normally closed contact)

⑤Mounted type: Retaining bolt installation

⑥Auxiliary function: D/CR Inhibitory protection

⑦Coil voltage: (DC: direct voltage  AC: alternating voltage)

 

Contact parameters

Contact form 1Z
contact resistance 100mΩ
Contact material AgSnO2
Contact load (resistive) 250A  250VAC/30VDC

Product Technical Parameters

Contact Contact form 1Z
Contact load (resistive) 250A 250VAC/30VDC
Electrical life ≥3×10⁴ times
Mechanical life ≥10⁶ times
Contact resistance ≤100mΩ
Contact material AgSnO2
Terminal type Insulation resistance MΩ ≥200MΩ(500VDC)
Dielectric strength Between the same pole contacts

≥1000VAC/1min

/
Between contact and coil

≥2500VAC/1min

Suction time ≤25ms
Release time ≤25ms
Terminal type Screw type
Coil Rated coil power DC: 2.0W AC: 4VA

Product Size and Installation

 

 

Selection Guide

Unless otherwise specified, all load currents indicated on the Hangwang relay case are for resistive loads. Under the rated switching voltage, the allowable current of inductive loads should not exceed 30% of the rated resistive loads, the allowable current of motor loads should not exceed 20% of the rated resistive loads, the allowable current of lamp loads should not exceed 10% of the rated resistive loads, and the allowable current of capacitive loads should not exceed 5% of the rated resistive loads. In order to ensure the reliability of the product, it is recommended that the contact load current value should not exceed 60% – 70% of the steady state current value under the rated load of the product.

Nature of the load Inrush current
Resistive load 1 times the steady-state current
Sodium lamp load 1-3 times the steady-state current
Mercury-vapor lamp load 3 times the steady state current
Inductive load 3-5 times the steady-state current
Motor load 3-5 times the steady-state current
Voltage load 3-5 times the steady-state current
Incandescent lamp load 3-5 times the steady-state current
Capacitive load 3-5 times the steady-state current

 

For more information on relay selection, please view the Selection Guide . Also, to ensure that you use our products correctly and safely, be sure to read the Matters Needing Attention .