Virtue To Sincerity
Precision To Goodness

HW-Y2CL Industrial Relay LED, Patented Design, Durable

Additional information

Contact resistance

≤50mΩ

Electrical life

≥10⁵ times

Mechanical life

≥10⁷ times

Coil voltage

DC: 6-220V AC: 6-380V

Operate time

≤15ms

Share To:

Model:HW-Y2CL

Product Characteristics:

①Products have series, basic type, improved type, functional type and so on.

②Novel structure, ingenious design, beautiful and generous appearance, high resistance to electricity, with multiple patents.

③Working status LED indication, coil voltage DC with LED type optional infinite input.

④Improved and functional relay housings feature a variety of fixed circlip mounting designs.

 

Model Description

HW Y 2 Optional Optional L D VDC

①Enterprise code: Hangwang Electric

②Serial number: L

③Number of contact groups: 2

④Contact form: (Z-conversion type  H-normally open type  D-normally closed contact)

⑤Mounted type:F:flange mounted type  P: PCB mounted type  No letters: plug-in mounted

⑥Operating state: L: LED indicate  No letters: no indicate

⑦Auxiliary function: D/CR Inhibitory protection

⑧Coil voltage: (DC: direct voltage  AC: alternating voltage)

 

For more detailed and accurate parameters, please contact our customer service personnel for answers.

Description of contact forms

Name Domestic code International  code Structural form
Conversion type Z C
Normally open H A
Normally closed D B

Switching type:

The center is a moving contact, coil is not energized, the moving contact and one of the static contact is disconnected and the other one is closed, after the coil is energized, the moving contact will move, so that the original disconnected into a closed state, the original closed into a disconnected state, to achieve the purpose of conversion.

Normally open type:

The contacts are open when the coil is not energized and closed when energized.

Normally closed type:

The contacts are closed when the coil is not energized, and the contacts are closed when energized.

Product Technical Parameters

Model HW-Y2CL
Dimension士0.5mm 27.4 ×21 × 35.4mm
Contact form 2(A B C)
Contact material Silver alloy AgCdO AgSno2
Contact capacity (resistive) 10A

28VDC/240VAC

Contact resistance ≤50mΩ
Coil power AC 1.2VA
DC 0.9W
Coil voltage AC 6~380VAC
DC 6~220VDC
Operate time ≤15ms
Release time ≤15ms
Pick-up voltage DC:≤75%  AC:≤80%
Drop-out voltage DC:≥10%  AC:≥30%
Max voltage 110%
Dielectric strength Between the same pole contacts 1000VAC/1min(Leakage current 1mA)
Between opposite pole contacts 1200VAC/1min(Leakage current 1mA)
Between contact and coil 1500VAC/1min(Leakage current 1mA)
Insulation resistance ≥500MΩ(500VDC)
Service life Electrical life 1×10⁵ times
Mechanical life 1×10⁷times
Ambient temperature(℃) -25°C ~ +55°C
Ambient humidity 35%~85%RH
Atmospheric pressure 86~106KPa
Shock resistance 10G (Sine wave half pulse: 11ms)
Vibration resistance 10~55Hz(Double amplitude: 1mm)
Terminal type Insert type
Protection type Close type
Suitable socket PYF08A
Product weight(g) about 35g

Product Size and Installation

 

Selection Guide

Unless otherwise specified, all load currents indicated on the Hangwang relay case are for resistive loads. Under the rated switching voltage, the allowable current of inductive loads should not exceed 30% of the rated resistive loads, the allowable current of motor loads should not exceed 20% of the rated resistive loads, the allowable current of lamp loads should not exceed 10% of the rated resistive loads, and the allowable current of capacitive loads should not exceed 5% of the rated resistive loads. In order to ensure the reliability of the product, it is recommended that the contact load current value should not exceed 60% – 70% of the steady state current value under the rated load of the product.

Nature of the load Inrush current
Resistive load 1 times the steady-state current
Sodium lamp load 1-3 times the steady-state current
Mercury-vapor lamp load 3 times the steady state current
Inductive load 3-5 times the steady-state current
Motor load 3-5 times the steady-state current
Voltage load 3-5 times the steady-state current
Incandescent lamp load 3-5 times the steady-state current
Capacitive load 3-5 times the steady-state current

Matters needing attention

①Please do not touch the relay terminals and the connected electrical accessories under the energized state, and cut off the power supply when installing, maintaining and troubleshooting the relays (including terminal blocks, sockets and other connected parts). If you need technical support, please contact the service center of Hangwang Electrical Appliances.

②Do not use the relay beyond the rated load. Overloading may cause insulation degradation, contact sticking, poor contact and other malfunctions, and may even cause the relay itself to break and burn out. If you need technical support, please contact Hangwang Electrical Service Center.

③Please avoid dropping the product during storage and use, and do not disassemble the internal components. To avoid damage, burnout and electric shock. If you need technical support, please contact Hangwang Electrical Service Center.

④Do not use it in flammable or explosive gas environment. And avoid using in the place where there is water, steam, melting phenomenon after icing or water droplets falling. If you need technical support, please contact the service center of Hangwang Electrical Appliances.

⑤The rated performance values in the data sheet, if not specified, are the values under the standard test conditions of JIS C5442 (temperature +15°C ~ +35°C, relative humidity 25 ~ 75%, air pressure 86 ~ 106KPa). In addition to the load conditions, the operating environment must also be verified under the same conditions as the actual operating conditions when using the actual equipment. For technical support, please contact the service center.

⑥The coil of relay has polarity (positive and negative poles are marked on the wiring diagram), please check the wiring diagram before connecting the terminals, and then connect the wires correctly, it is strictly prohibited to connect the terminals in reverse, if it is connected incorrectly, it will cause malfunction, abnormal heat and fire. If you need technical support, please contact the service center of Hangwang Electrical Appliances.

⑦Avoid continuously applying voltage to the coil exceeding the maximum switching voltage. If you need technical support, please contact the service center of Hangwang Electrical Appliances.

⑧ For more technical problems, please contact our service center. Tel:155-5873-3666

Get Professional Consulting Services From Hangwang Electrical Immediately

Your email information is completely secure and will not be disclosed to third parties for any reason.

Interested In Our Relay Products?

Get the latest product brochures and technical data.