Virtue To Sincerity
Precision To Goodness

HW-L3C-P Electromagnetic Relay 10A, LED, Compact & Durable

Additional information

Contact resistance

≤100mΩ

Electrical life

≥10⁵ times

Mechanical life

≥10⁷ times

Coil voltage

DC: 6-220V AC: 6-380V

Suction time

≤15ms

Share To:

Model:HW-L3C-P

Product Characteristics:

①Small size, light weight, high sensitivity, long service life.

②Provide 3 set 10A of contact conversion.

③The products have series, basic type, improved type and functional type.

④Working status LED indication, coil voltage DC with LED type optional infinite input.

⑤Novel structure, ingenious design, beautiful appearance, high resistance to electricity, with multiple patents.

⑥Improved and functional relay cover has a variety of fixed circlip design for mounting.

Model Description

HW L 3 Optional Optional Optional Optional VDC

①Enterprise code: Hangwang Electric

②Serial number: L

③Number of contact groups: 3

④Contact form: (Z-conversion type  H-normally open type  D-normally closed contact)

⑤Mounted type:F:flange mounted type  P: PCB mounted type  No letters: plug-in mounted

⑥Operating state: L: LED indicate  No letters: no indicate

⑦Auxiliary function: D/CR Inhibitory protection

⑧Coil voltage: (DC: direct voltage  AC: alternating voltage)

 

For more detailed and accurate parameters, please contact our customer service personnel for answers.

Contact parameters

Contact form 3Z,3H,3D
Contact load 10A
Maximum switching voltage 240VAC 10A
28VDC 10A
Contact material Silver alloy

Description of contact forms

Name Domestic code International  code Structural form
Conversion type Z C
Normally open H A
Normally closed D B

Switching type:

The center is a moving contact, coil is not energized, the moving contact and one of the static contact is disconnected and the other one is closed, after the coil is energized, the moving contact will move, so that the original disconnected into a closed state, the original closed into a disconnected state, to achieve the purpose of conversion.

Normally open type:

The contacts are open when the coil is not energized and closed when energized.

Normally closed type:

The contacts are closed when the coil is not energized, and the contacts are closed when energized.

Operating Coils

Rated voltage V DC12V DC24V DC110V DC220V
Rated current(+10%)mA 125 62.5 13.6 6.8
Coil resistance(+10%)Ω 100 400 8400 33000
Rated power consumption W 0.9W
Pick-up voltage(max)V Less than 75%
Drop-out voltage (min) V 10% or more
Allowable voltage(max) V Rated voltage ×110%

 

Rated voltage V AC12V AC24V AC110V AC220V
Rated current(+10%)mA 208 104 22.7 11.3
Coil resistance(+10%)Ω 25.5 102 2300 8600
Rated power consumption W 1.2VA
Pick-up voltage(max)V Less than 80%
Drop-out voltage (min) V 30% or more
Allowable voltage(max) V Rated voltage ×110%

Product Technical Parameters

Contact resistance ≤100mΩ
Electrical life ≥10⁵ times
Mechanical life ≥107 times
Coil voltage DC: 6-220V AC: 6-380V
Suction time ≤15ms
Release time ≤15ms
Between the same pole contacts 1000VAC/1min(Leakage current 1mA)
Between opposite pole contacts 1200VAC/1min(Leakage current 1mA)
Between contact and coil 1500VAC/1min(Leakage current 1mA)
Insulation resistance ≥500MΩ(500VDC)
Ambient temperature -25°C ~ +55°C
Ambient humidity 35% ~ 80%RH
Atmospheric pressure 86 ~ 106KPa
Impact resistance 10G (Sine wave half pulse: 11ms)
Vibration resistance 10-55Hz (Double amplitude: 1.5mm)
Dimensions 27.3 × 31 ×35mm
Weight About 50g

Product Size and Installation

 

Selection Guide

Unless otherwise specified, all load currents indicated on the Hangwang relay case are for resistive loads. Under the rated switching voltage, the allowable current of inductive loads should not exceed 30% of the rated resistive loads, the allowable current of motor loads should not exceed 20% of the rated resistive loads, the allowable current of lamp loads should not exceed 10% of the rated resistive loads, and the allowable current of capacitive loads should not exceed 5% of the rated resistive loads. In order to ensure the reliability of the product, it is recommended that the contact load current value should not exceed 60% – 70% of the steady state current value under the rated load of the product.

Nature of the load Inrush current
Resistive load 1 times the steady-state current
Sodium lamp load 1-3 times the steady-state current
Mercury-vapor lamp load 3 times the steady state current
Inductive load 3-5 times the steady-state current
Motor load 3-5 times the steady-state current
Voltage load 3-5 times the steady-state current
Incandescent lamp load 3-5 times the steady-state current
Capacitive load 3-5 times the steady-state current

Matters needing attention

①Please do not touch the relay terminals and the connected electrical accessories under the energized state, and cut off the power supply when installing, maintaining and troubleshooting the relays (including terminal blocks, sockets and other connected parts). If you need technical support, please contact the service center of Hangwang Electrical Appliances.

②Do not use the relay beyond the rated load. Overloading may cause insulation degradation, contact sticking, poor contact and other malfunctions, and may even cause the relay itself to break and burn out. If you need technical support, please contact Hangwang Electrical Service Center.

③Please avoid dropping the product during storage and use, and do not disassemble the internal components. To avoid damage, burnout and electric shock. If you need technical support, please contact Hangwang Electrical Service Center.

④Do not use it in flammable or explosive gas environment. And avoid using in the place where there is water, steam, melting phenomenon after icing or water droplets falling. If you need technical support, please contact the service center of Hangwang Electrical Appliances.

⑤The rated performance values in the data sheet, if not specified, are the values under the standard test conditions of JIS C5442 (temperature +15°C ~ +35°C, relative humidity 25 ~ 75%, air pressure 86 ~ 106KPa). In addition to the load conditions, the operating environment must also be verified under the same conditions as the actual operating conditions when using the actual equipment. For technical support, please contact the service center.

⑥The coil of relay has polarity (positive and negative poles are marked on the wiring diagram), please check the wiring diagram before connecting the terminals, and then connect the wires correctly, it is strictly prohibited to connect the terminals in reverse, if it is connected incorrectly, it will cause malfunction, abnormal heat and fire. If you need technical support, please contact the service center of Hangwang Electrical Appliances.

⑦Avoid continuously applying voltage to the coil exceeding the maximum switching voltage. If you need technical support, please contact the service center of Hangwang Electrical Appliances.

⑧ For more technical problems, please contact our service center. Tel:155-5873-3666

Get Professional Consulting Services From Hangwang Electrical Immediately

Your email information is completely secure and will not be disclosed to third parties for any reason.

Interested In Our Relay Products?

Get the latest product brochures and technical data.