Power Relay

HW-250F Power Relay 250A, Durable, Bolt Mounting

HW-250F power relay offers 250A contact conversion, strong impact and vibration resistance, and long service life. Features retaining bolt installation

Contact resistance≤100mΩ
Electrical life≥3×10⁴ times
Mechanical life≥10⁶ times
Rated coil powerDC: 2.0W AC: 4VA
Suction time≤25ms

Model Description

HW250F1OptionalOptionalDVDC

①Enterprise code: Hangwang Electric

②Serial number: 250F

③Number of contact groups: 1

④Contact form: (Z-conversion type  H-normally open type  D-normally closed contact)

⑤Mounted type: Retaining bolt installation

⑥Auxiliary function: D/CR Inhibitory protection

⑦Coil voltage: (DC: direct voltage  AC: alternating voltage)

 

Contact parameters

Contact form1Z
contact resistance100mΩ
Contact materialAgSnO2
Contact load (resistive)250A  250VAC/30VDC

Product Technical Parameters

ContactContact form1Z
Contact load (resistive)250A 250VAC/30VDC
Electrical life≥3×10⁴ times
Mechanical life≥10⁶ times
Contact resistance≤100mΩ
Contact materialAgSnO2
Terminal typeInsulation resistance MΩ≥200MΩ(500VDC)
Dielectric strengthBetween the same pole contacts

≥1000VAC/1min

/
Between contact and coil

≥2500VAC/1min

Suction time≤25ms
Release time≤25ms
Terminal typeScrew type
CoilRated coil powerDC: 2.0W AC: 4VA

Product Size and Installation

 

 

Selection Guide

Unless otherwise specified, all load currents indicated on the Hangwang relay case are for resistive loads. Under the rated switching voltage, the allowable current of inductive loads should not exceed 30% of the rated resistive loads, the allowable current of motor loads should not exceed 20% of the rated resistive loads, the allowable current of lamp loads should not exceed 10% of the rated resistive loads, and the allowable current of capacitive loads should not exceed 5% of the rated resistive loads. In order to ensure the reliability of the product, it is recommended that the contact load current value should not exceed 60% – 70% of the steady state current value under the rated load of the product.

Nature of the loadInrush current
Resistive load1 times the steady-state current
Sodium lamp load1-3 times the steady-state current
Mercury-vapor lamp load3 times the steady state current
Inductive load3-5 times the steady-state current
Motor load3-5 times the steady-state current
Voltage load3-5 times the steady-state current
Incandescent lamp load3-5 times the steady-state current