Model Description
HW |
MK |
2 |
Optional |
Optional |
L |
D |
VDC |
① |
② |
③ |
④ |
⑤ |
⑥ |
⑦ |
⑧ |
①Enterprise code: Hangwang Electric
②Serial number: MK
③Number of contact groups: 2
④Contact form: (Z-conversion type H-normally open type D-normally closed contact)
⑤Mounted type: P: PCB mounted type No letters: plug-in mounted
⑥Operating state: L: LED indicate No letters: no indicate
⑦Auxiliary function: D/CR Inhibitory protection
⑧Coil voltage: (DC: direct voltage AC: alternating voltage)
Contact parameters
Contact form |
2Z,2H,2D |
Contact load |
10A |
Maximum switching voltage |
240VAC 5A
28VDC 5A |
Contact material |
Silver alloy |
Operating Coils
Rated voltage V |
DC12V |
DC24V |
DC110V |
DC220V |
Rated current(+10%)mA |
150 |
75 |
16.3 |
8.1 |
Coil resistance(+10%)Ω |
80 |
320 |
6748 |
27160 |
Rated power consumption W |
2W |
Pick-up voltage(max)V |
Less than 75% |
Drop-out voltage (min) V |
10% or more |
Allowable voltage(max) V |
Rated voltage ×110% |
Rated voltage V |
AC12V |
AC24V |
AC110V |
AC220V |
Rated current(+10%)mA |
225 |
112.5 |
24.5 |
12.3 |
Coil resistance(+10%)Ω |
18.7 |
74.7 |
1571 |
6260 |
Rated power consumption W |
3.5VA |
Pick-up voltage(max)V |
Less than 80% |
Drop-out voltage (min) V |
30% or more |
Allowable voltage(max) V |
Rated voltage ×110% |
Product Technical Parameters
Contact resistance |
≤100mΩ |
Electrical life |
≥10⁵ times |
Mechanical life |
≥10⁶ times |
Coil voltage |
DC: 6-220V AC: 6-380V |
Suction time |
≤20ms |
Release time |
≤15ms |
Between the same pole contacts |
1000VAC/1min(Leakage current 1mA) |
Between opposite pole contacts |
1000VAC/1min(Leakage current 1mA) |
Between contact and coil |
1500VAC/1min(Leakage current 1mA) |
Insulation resistance |
≥100MΩ(500VDC) |
Ambient temperature |
-25°C ~ +55°C |
Ambient humidity |
35% ~ 80%RH |
Atmospheric pressure |
86 ~ 106KPa |
Impact resistance |
10G (Sine wave half pulse: 11ms) |
Vibration resistance |
10-55Hz (Double amplitude: 1.5mm) |
Dimensions |
35 × 35 ×55mm |
Weight |
About 75g |
Product Size and Installation

Selection Guide
Unless otherwise specified, all load currents indicated on the Hangwang relay case are for resistive loads. Under the rated switching voltage, the allowable current of inductive loads should not exceed 30% of the rated resistive loads, the allowable current of motor loads should not exceed 20% of the rated resistive loads, the allowable current of lamp loads should not exceed 10% of the rated resistive loads, and the allowable current of capacitive loads should not exceed 5% of the rated resistive loads. In order to ensure the reliability of the product, it is recommended that the contact load current value should not exceed 60% – 70% of the steady state current value under the rated load of the product.
Nature of the load |
Inrush current |
Resistive load |
1 times the steady-state current |
Sodium lamp load |
1-3 times the steady-state current |
Mercury-vapor lamp load |
3 times the steady state current |
Inductive load |
3-5 times the steady-state current |
Motor load |
3-5 times the steady-state current |
Voltage load |
3-5 times the steady-state current |
Incandescent lamp load |
3-5 times the steady-state current |
Capacitive load |
3-5 times the steady-state current |