General Purpose Relay

HW-MK3P General Purpose Relay 10A, 3 Contacts, Socket Mount

HW-MK3P general purpose relay offers 3 sets of 10A contact conversion, high sensitivity, and long service life. Socket mounted with optional indicator lamps and diodes

Contact resistance≤100mΩ
Electrical life≥10⁵ times
Mechanical life≥10⁶ times
Coil voltageDC: 6-220V AC: 6-380V
Suction time≤20ms

Model Description

HWMK3OptionalOptionalLDVDC

①Enterprise code: Hangwang Electric

②Serial number: MK

③Number of contact groups: 3

④Auxiliary function: T:self-locking  G-mechanical indicate  D/CR-Inhibitory protection

⑤Mounted type: P: PCB mounted type  No letters: plug-in mounted

⑥Operating state: L: LED indicate  No letters: no indicate

⑦Coil voltage: (DC: direct voltage  AC: alternating voltage

 

Contact parameters

Contact form3Z,3H,3D
Contact load10A
Maximum switching voltage240VAC 5A
28VDC 5A
Contact materialSilver alloy

Operating Coils

Rated voltage VDC12VDC24VDC110VDC220V
Rated current(+10%)mA1507516.38.1
Coil resistance(+10%)Ω80320674827160
Rated power consumption W2W
Pick-up voltage(max)VLess than 75%
Drop-out voltage (min) V10% or more
Allowable voltage(max) VRated voltage ×110%

 

Rated voltage VAC12VAC24VAC110VAC220V
Rated current(+10%)mA225112.524.512.3
Coil resistance(+10%)Ω18.774.715716260
Rated power consumption W3.5VA
Pick-up voltage(max)VLess than 80%
Drop-out voltage (min) V30% or more
Allowable voltage(max) VRated voltage ×110%

Product Technical Parameters

Contact resistance≤100mΩ
Electrical life≥10⁵ times
Mechanical life≥10⁶ times
Coil voltageDC: 6-220V AC: 6-380V
Suction time≤20ms
Release time≤15ms
Between the same pole contacts1000VAC/1min(Leakage current 1mA)
Between opposite pole contacts1000VAC/1min(Leakage current 1mA)
Between contact and coil1500VAC/1min(Leakage current 1mA)
Insulation resistance≥100MΩ(500VDC)
Ambient temperature-25°C ~ +55°C
Ambient humidity35% ~ 80%RH
Atmospheric pressure86 ~ 106KPa
Impact resistance10G (Sine wave half pulse: 11ms)
Vibration resistance10-55Hz (Double amplitude: 1.5mm)
Dimensions35 × 35 ×55mm
WeightAbout 75g

Product Size and Installation

Selection Guide

Unless otherwise specified, all load currents indicated on the Hangwang relay case are for resistive loads. Under the rated switching voltage, the allowable current of inductive loads should not exceed 30% of the rated resistive loads, the allowable current of motor loads should not exceed 20% of the rated resistive loads, the allowable current of lamp loads should not exceed 10% of the rated resistive loads, and the allowable current of capacitive loads should not exceed 5% of the rated resistive loads. In order to ensure the reliability of the product, it is recommended that the contact load current value should not exceed 60% – 70% of the steady state current value under the rated load of the product.

Nature of the loadInrush current
Resistive load1 times the steady-state current
Sodium lamp load1-3 times the steady-state current
Mercury-vapor lamp load3 times the steady state current
Inductive load3-5 times the steady-state current
Motor load3-5 times the steady-state current
Voltage load3-5 times the steady-state current
Incandescent lamp load3-5 times the steady-state current
Capacitive load3-5 times the steady-state current

 